ZITARES QCS Art. no.: 10118439
Output power: 22 ... 40 W Output current: 1 x 700 mA Output voltage: 32 ... 56 V Dimensions: 165 x 41 x 33 [mm]

additional
Sample image
  • CE.png
  • CQS.png
  • RCM_Logo.png
  • 1101.png
  • Schutzklasse2.png
  • SELV.png
  • Unabhaengige_Betriebsgeraete.png
  • ENEC 05.png

Operation data

Output power: 22 ... 40 W
Output current: 1 x 700 mA
Output voltage: 32 ... 56 V
U-OUT: 60 V
ECG efficiency: 88 %
Power factor: 0.96
:

Technical data

Mains voltage supply

Rated voltage range 220 ... 240 [V]
Rated frequency 50 ... 60 [Hz]

Behaviour at mains overvoltage

Overvoltage protection 320 VAC

Output data

Output current tolerance (output) ≤ +/- 10 %
Ripple output current (low frequency) (output) ≤ +/- 22 %
Galvanic separation to mains input yes, testing voltage 3.75 kV

Temperatures

Max. admissible case temperature tc,max 75 °C

Performance characteristics

  • Non-dimmable 1-channel ECG for constant current operation of LED modules
  • SELV output voltage ≤ 60 VDC for simplified luminaire construction
  • Very high efficiency of up to 88 % at maximum output load
  • ECG extensively protected against abnormal operating conditions at the output, e.g. short-circuit, open circuit or overload
  • Certified as thermally protected ECG
  • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference
  • Nominal service lifetime with a failure rate ≤ 10 %:
    • 50.000 h bei tc = tc,max
    • 30.000 h bei tc = tc,max -10 K

Measurements and weight

Dimensions and weights
Net Weight: 0.175 kg
Length (X): 165 mm
Width (Y): 41 mm
Height (Z): 33 mm
Hole spacing (Xm): 156.4 mm